Specifications and Environment
A-3
Power Requirements and Environment
The following power requirements and environmental specifications apply to
InterScan Gateway Security Appliance::
TABLE A-1. Appliance power requirements and environmental specifications
Element Specification
AC input voltage 90 to 264VAC (100 to 240 nominal)
AC input current (90VAC) 8.0A
AC input current (180VAC) 4.0A
Frequency 47 to 63Hz (50/60 nominal)
NORMAL OPERATING AMBIENT TEMPERATURE (AT SEA LEVEL)
Minimum (operating and idle) 32°F (0°C)
Maximum (operating, power supply on) 104°F (40°C)
Maximum rate of change 50°F per hour (10°C per hour)
STORAGE TEMPERATURE (AT SEA LEVEL)
Minimum -4°F (-20°C)
Maximum 158°F (70°C)
Maximum rate of change 68°F per hour (15°C per hour)
HUMIDITY
Maximum (operating) 80% non-condensing
Maximum (non-operating) 95% non-condensing